{"id":35,"date":"2013-02-01T04:04:13","date_gmt":"2013-02-01T04:04:13","guid":{"rendered":"http:\/\/www.oshimalab.iis.u-tokyo.ac.jp\/english\/?page_id=35"},"modified":"2018-08-12T16:53:29","modified_gmt":"2018-08-12T07:53:29","slug":"research","status":"publish","type":"page","link":"https:\/\/www.oshimalab.iis.u-tokyo.ac.jp\/english\/research\/","title":{"rendered":"Research"},"content":{"rendered":"<p style=\"text-align: center;\">We are interested in the integration of the fluid engineering knowledge and technology into the biomedical field in an effort to open a new frontier in the interdisciplinary research. Our two specific research targets are the hemodynamics in the cerebral artery, and the micro\/nanofluidics in Micro-TAS or Lab-on-a-chip through the following approaches, the numerical simulation (FEM , etc.) and the visual sensing (PIV).<\/p>\n<p>&nbsp;<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"wp-image-555 size-medium aligncenter\" src=\"http:\/\/www.oshimalab.iis.u-tokyo.ac.jp\/english\/wp-content\/uploads\/2013\/02\/V-Modeler_GUI-300x220.jpg\" width=\"300\" height=\"220\" srcset=\"https:\/\/www.oshimalab.iis.u-tokyo.ac.jp\/english\/wp-content\/uploads\/2013\/02\/V-Modeler_GUI-300x220.jpg 300w, https:\/\/www.oshimalab.iis.u-tokyo.ac.jp\/english\/wp-content\/uploads\/2013\/02\/V-Modeler_GUI-768x564.jpg 768w, https:\/\/www.oshimalab.iis.u-tokyo.ac.jp\/english\/wp-content\/uploads\/2013\/02\/V-Modeler_GUI-600x441.jpg 600w, https:\/\/www.oshimalab.iis.u-tokyo.ac.jp\/english\/wp-content\/uploads\/2013\/02\/V-Modeler_GUI.jpg 847w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><\/p>\n<p style=\"text-align: center;\">3D modeling system of blood vessel from medical image<\/p>\n<p style=\"text-align: center;\"><a class=\"button default small \" href=\"http:\/\/www.oshimalab.iis.u-tokyo.ac.jp\/english\/research\/3d_modeling\" target=\"_self\">Click for More<\/a><\/p>\n<p style=\"text-align: center;\"><img loading=\"lazy\" decoding=\"async\" class=\"wp-image-475 size-medium alignnone\" src=\"http:\/\/www.oshimalab.iis.u-tokyo.ac.jp\/english\/wp-content\/uploads\/2014\/11\/\u56f31-300x131.png\" width=\"300\" height=\"131\" srcset=\"https:\/\/www.oshimalab.iis.u-tokyo.ac.jp\/english\/wp-content\/uploads\/2014\/11\/\u56f31-300x131.png 300w, https:\/\/www.oshimalab.iis.u-tokyo.ac.jp\/english\/wp-content\/uploads\/2014\/11\/\u56f31-1024x449.png 1024w, https:\/\/www.oshimalab.iis.u-tokyo.ac.jp\/english\/wp-content\/uploads\/2014\/11\/\u56f31-600x263.png 600w, https:\/\/www.oshimalab.iis.u-tokyo.ac.jp\/english\/wp-content\/uploads\/2014\/11\/\u56f31.png 1066w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><\/p>\n<p style=\"text-align: center;\">Cerebral circulation model for multiscale blood flow analysis<\/p>\n<p style=\"text-align: center;\"><a class=\"button default small \" href=\"http:\/\/www.oshimalab.iis.u-tokyo.ac.jp\/english\/research\/cerebral-circulation-model-for-multiscale-blood-flow-analysis\">Click for More<\/a><\/p>\n<p><a href=\"http:\/\/www.oshimalab.iis.u-tokyo.ac.jp\/english\/wp-content\/uploads\/2013\/02\/6-1.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-medium wp-image-282\" src=\"http:\/\/www.oshimalab.iis.u-tokyo.ac.jp\/english\/wp-content\/uploads\/2013\/02\/6-1-300x171.jpg\" alt=\"\" width=\"300\" height=\"171\" srcset=\"https:\/\/www.oshimalab.iis.u-tokyo.ac.jp\/english\/wp-content\/uploads\/2013\/02\/6-1-300x171.jpg 300w, https:\/\/www.oshimalab.iis.u-tokyo.ac.jp\/english\/wp-content\/uploads\/2013\/02\/6-1.jpg 350w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><\/a><\/p>\n<p style=\"text-align: center;\">Modeling of outflow boundary conditions<\/p>\n<p style=\"text-align: center;\"><a class=\"button default small \" href=\"http:\/\/www.oshimalab.iis.u-tokyo.ac.jp\/english\/research\/hemodynamic-simulation\" target=\"_self\">Click for More<\/a><\/p>\n<p>&nbsp;<\/p>\n<p><iframe loading=\"lazy\" title=\"FSI simulation of Aneurysm model\" width=\"584\" height=\"329\" src=\"https:\/\/www.youtube.com\/embed\/of5X0rf2y04?feature=oembed\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\" allowfullscreen><\/iframe><\/p>\n<div class=\"one_half last\">\n<p style=\"text-align: center;\">Fluid-structure interaction (FSI) analysis of aneurysm model considering deformation of blood vessel wall<\/p>\n<p style=\"text-align: center;\"><a class=\"button default small \" href=\"http:\/\/www.oshimalab.iis.u-tokyo.ac.jp\/english\/research\/fluid-structure-interaction-fsi-analysis-of-aneurysm-model-considering-deformation-of-blood-vessel-wall\">Click for More<\/a><\/p>\n<p>&nbsp;<\/p>\n<\/div>\n<p><iframe loading=\"lazy\" title=\"Development of an integrated 1D-0D simulation system for patient-specific cerebral circulation\" width=\"584\" height=\"329\" src=\"https:\/\/www.youtube.com\/embed\/0dIVvK2bCoE?feature=oembed\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\" allowfullscreen><\/iframe><\/p>\n<div class=\"one_half last\">\n<p style=\"text-align: center;\">3D visualization system of 1D-0D blood flow simulation results<\/p>\n<p style=\"text-align: center;\"><a class=\"button default small \" href=\"http:\/\/www.oshimalab.iis.u-tokyo.ac.jp\/english\/research\/3d-visualization-system-of-1d-0d-blood-flow-simulation-results\">Click for More<\/a><\/p>\n<\/div>\n<p>&nbsp;<\/p>\n<p><a href=\"http:\/\/www.oshimalab.iis.u-tokyo.ac.jp\/english\/wp-content\/uploads\/2013\/02\/8-3.png\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-medium wp-image-297\" src=\"http:\/\/www.oshimalab.iis.u-tokyo.ac.jp\/english\/wp-content\/uploads\/2013\/02\/8-3-300x207.png\" alt=\"\" width=\"300\" height=\"207\" srcset=\"https:\/\/www.oshimalab.iis.u-tokyo.ac.jp\/english\/wp-content\/uploads\/2013\/02\/8-3-300x207.png 300w, https:\/\/www.oshimalab.iis.u-tokyo.ac.jp\/english\/wp-content\/uploads\/2013\/02\/8-3.png 560w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><\/a><\/p>\n<p style=\"text-align: center;\">Blood Flow Model taking account of Mass Transport<\/p>\n<p style=\"text-align: center;\"><a class=\"button default small \" href=\"http:\/\/www.oshimalab.iis.u-tokyo.ac.jp\/english\/research\/blood-flow-model-taking-account-of-mass-transport\">Click for More<\/a><\/p>\n<div class=\"one_half last\"><a href=\"http:\/\/www.oshimalab.iis.u-tokyo.ac.jp\/english\/wp-content\/uploads\/2013\/02\/Res_Exp_multi_micro_clip_image002_0010.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-medium wp-image-199\" src=\"http:\/\/www.oshimalab.iis.u-tokyo.ac.jp\/english\/wp-content\/uploads\/2013\/02\/Res_Exp_multi_micro_clip_image002_0010-220x300.jpg\" alt=\"\" width=\"220\" height=\"300\" srcset=\"https:\/\/www.oshimalab.iis.u-tokyo.ac.jp\/english\/wp-content\/uploads\/2013\/02\/Res_Exp_multi_micro_clip_image002_0010-220x300.jpg 220w, https:\/\/www.oshimalab.iis.u-tokyo.ac.jp\/english\/wp-content\/uploads\/2013\/02\/Res_Exp_multi_micro_clip_image002_0010.jpg 268w\" sizes=\"(max-width: 220px) 100vw, 220px\" \/><\/a><\/div>\n<div class=\"one_half last\"><\/div>\n<div class=\"one_half last\">\n<p style=\"text-align: center;\">Multicolor confocal micro-PIV system for micro multiphase flow measurement<\/p>\n<p style=\"text-align: center;\"><a class=\"button default small \" href=\"http:\/\/www.oshimalab.iis.u-tokyo.ac.jp\/english\/research\/confocal-micro-piv\" target=\"_self\">Click for More<\/a><\/p>\n<p>&nbsp;<\/p>\n<\/div>\n<div class=\"one_half last\">\n<p><a href=\"http:\/\/www.oshimalab.iis.u-tokyo.ac.jp\/english\/wp-content\/uploads\/2013\/05\/image007.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-medium wp-image-432\" src=\"http:\/\/www.oshimalab.iis.u-tokyo.ac.jp\/english\/wp-content\/uploads\/2013\/05\/image007-300x274.jpg\" alt=\"\" width=\"300\" height=\"274\" srcset=\"https:\/\/www.oshimalab.iis.u-tokyo.ac.jp\/english\/wp-content\/uploads\/2013\/05\/image007-300x274.jpg 300w, https:\/\/www.oshimalab.iis.u-tokyo.ac.jp\/english\/wp-content\/uploads\/2013\/05\/image007.jpg 384w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><\/a><\/p>\n<p style=\"text-align: center;\">Confocal micro-PIV Measurement of the Interaction between Red Blood Cells and Surrounding Flow<\/p>\n<p style=\"text-align: center;\"><a class=\"button default small \" href=\"http:\/\/www.oshimalab.iis.u-tokyo.ac.jp\/english\/research\/red-blood-cell-motion\">Click for More<\/a><\/p>\n<p><a href=\"http:\/\/www.oshimalab.iis.u-tokyo.ac.jp\/english\/wp-content\/uploads\/2013\/02\/doumyaku_ryu_bando1.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-medium wp-image-609\" src=\"http:\/\/www.oshimalab.iis.u-tokyo.ac.jp\/english\/wp-content\/uploads\/2013\/02\/doumyaku_ryu_bando1-300x167.jpg\" alt=\"\" width=\"300\" height=\"167\" srcset=\"https:\/\/www.oshimalab.iis.u-tokyo.ac.jp\/english\/wp-content\/uploads\/2013\/02\/doumyaku_ryu_bando1-300x167.jpg 300w, https:\/\/www.oshimalab.iis.u-tokyo.ac.jp\/english\/wp-content\/uploads\/2013\/02\/doumyaku_ryu_bando1.jpg 360w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><\/a><\/p>\n<\/div>\n<div class=\"one_half last\" style=\"text-align: center;\">\n<p>\u00a0Stereoscopic PIV measurement in cerebral artery model<\/p>\n<p style=\"text-align: center;\"><a class=\"button default small \" href=\"http:\/\/www.oshimalab.iis.u-tokyo.ac.jp\/english\/research\/stereoscopic-piv-measurement-in-cerebral-artery\">Click for More<\/a><\/p>\n<p style=\"text-align: center;\">\n<\/div>\n<div class=\"one_half last\"><\/div>\n<div class=\"one_half last\">\n<p><iframe loading=\"lazy\" title=\"secondary flow structure in the cross section of curved pipe measured by dynamic stereo-PIV\" width=\"584\" height=\"329\" src=\"https:\/\/www.youtube.com\/embed\/gmCXEEcfu5c?feature=oembed\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\" allowfullscreen><\/iframe><\/p>\n<\/div>\n<div class=\"one_half last\">\n<p style=\"text-align: center;\">\u00a0Time-resolved Stereo PIV Measurement of Pulsatile Flow in the Modeled Artery<\/p>\n<p style=\"text-align: center;\"><a class=\"button default small \" href=\"http:\/\/www.oshimalab.iis.u-tokyo.ac.jp\/english\/research\/time-resolved-stereo-piv\">Click for More<\/a><\/p>\n<\/div>\n<div class=\"one_half last\">\u00a0<a href=\"http:\/\/www.oshimalab.iis.u-tokyo.ac.jp\/english\/wp-content\/uploads\/2013\/02\/4-4.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-268\" src=\"http:\/\/www.oshimalab.iis.u-tokyo.ac.jp\/english\/wp-content\/uploads\/2013\/02\/4-4.jpg\" alt=\"\" width=\"282\" height=\"213\" \/><\/a><\/div>\n<div class=\"one_half last\" style=\"text-align: center;\">\u00a0\u00a0Blood Vessel Depredation by Wall Shear Stress<\/div>\n<div class=\"one_half last\" style=\"text-align: center;\">\n<p style=\"text-align: center;\"><a class=\"button default small \" href=\"http:\/\/www.oshimalab.iis.u-tokyo.ac.jp\/english\/research\/blood-vessel-depredation\">Click for More<\/a><\/p>\n<\/div>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n","protected":false},"excerpt":{"rendered":"<p>We are interested in the integration of the fluid engineering knowledge and technology into the biomedical field in an effort to open a new frontier in the interdisciplinary research. Our two specific research targets are the hemodynamics in the cerebral &hellip; <a href=\"https:\/\/www.oshimalab.iis.u-tokyo.ac.jp\/english\/research\/\">Continue reading <span class=\"meta-nav\">&rarr;<\/span><\/a><\/p>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":3,"comment_status":"closed","ping_status":"closed","template":"page-sidebar-left.php","meta":{"footnotes":""},"_links":{"self":[{"href":"https:\/\/www.oshimalab.iis.u-tokyo.ac.jp\/english\/wp-json\/wp\/v2\/pages\/35"}],"collection":[{"href":"https:\/\/www.oshimalab.iis.u-tokyo.ac.jp\/english\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.oshimalab.iis.u-tokyo.ac.jp\/english\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.oshimalab.iis.u-tokyo.ac.jp\/english\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.oshimalab.iis.u-tokyo.ac.jp\/english\/wp-json\/wp\/v2\/comments?post=35"}],"version-history":[{"count":40,"href":"https:\/\/www.oshimalab.iis.u-tokyo.ac.jp\/english\/wp-json\/wp\/v2\/pages\/35\/revisions"}],"predecessor-version":[{"id":624,"href":"https:\/\/www.oshimalab.iis.u-tokyo.ac.jp\/english\/wp-json\/wp\/v2\/pages\/35\/revisions\/624"}],"wp:attachment":[{"href":"https:\/\/www.oshimalab.iis.u-tokyo.ac.jp\/english\/wp-json\/wp\/v2\/media?parent=35"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}